Send Email
Send SMS
Search
Sri Meenakshi Enterprises
Sri Meenakshi Enterprises


Power Line Transducers

Offering you a complete choice of products which include ac current transducers, frequency transducer, power factor transducers, ac voltage transducers, dc isolation transducer and tap position transducer.

AC Current Transducers

REQUEST CALLBACK

AC Current Transducers
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 2,773 / eachGet Latest Price

Product Details:
Minimum Order Quantity1 each
Transducer TypeAC Current Transducer
BrandMECO
Power85-265VAC/DC
Usage/ApplicationProcess Automation
Frequncy50Hz

We are listed amongst one of the renowned organizations in the domain, engaged in offering AC Current Transducers. Offered current transducer measure AC current and converts it into an industry standard output signal which is directly proportional to the measures input. We are providing this current transducer on diverse specifications as per the needs of customers. This current transducer is checked on well defined parameter for ensuring a flawless range.

Features:

  • Light in weight
  • User demanded processes
  • Gives load independent output

Additional Information:

  • Production Capacity: 5
  • Delivery Time: 1 week
  • Yes! I am interested

    View PDF

    Frequency Transducer

    REQUEST CALLBACK

    Frequency Transducer
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 3,000 / eachGet Latest Price

    Product Details:
    Minimum Order Quantity1 each
    BrandMECO
    Model Name/NumberFT
    Mounting TypeDIN RAIL MOUNTING
    Accuracy0.5

    Owing to our rich industry experience and knowledge, we are engaged in providing Frequency Transducer. The offered frequency transducers provide an output which is load independent and isolated from the input. These frequency transducers are developed by utilizing the excellent quality of material according to set market standards. Also, these frequency transducers are inspected by vendor’s quality controllers on pre-defined parameters for ensuring its defect free range.

    Features:

    • Perfect functionality
    • Output can be display or analysis
    • Operational fluency

    Specifications:
    StandardsIEC 688 / EN 60688, EN 61010-1, EN 61326-1, IS12784 (Part-1) 1989
    AC InputFrequency: 45-55, 45-65, 55-65, 360-440Hz
    Voltage : 63.5 / 110 / 230 / 440V (any one only)
    Auxiliary110/230V AC ± 20%
    24/48/110/220V DC ± 20%
    Self powered Available. Refer PDF
    IsolationComplete (Input / Output / Auxiliary / Case)
    TypeDIN Mounting, Back Panel Mounting
    DC OutputCurrent : 0-1, 0-5, 0-10, 2-10, 0-20, 4-20mA
    Voltage : 0-1, 0-5, 1-5, 0-10, 2-10V
    AccuracyStandard : ± 0.5% of Span
    Optional : On Request
    DielectricStrength 2.5kV at 50Hz for 1 min. (Standard)
    4kV(Optional), across
    Casing - Input / Output / Auxiliary
    Input - Output
    Input - Auxiliary
    Output - Auxiliary
    Output - Output (Optional, subject to technical feasibility)

    Additional Information:

  • Delivery Time: 30 days
  • Yes! I am interested

    View PDF

    Power Factor Transducers

    REQUEST CALLBACK

    Power Factor Transducers
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 6,600 / eachGet Latest Price

    Product Details:
    Minimum Order Quantity1 each
    BrandMECO
    Mounting TypeDIN RAIL MOUNTING
    Accuracy0.5
    Model Name/NumberPFT34 TRMS

    Our organization has gained immense recognition for offering quality assured Power Factor Transducers. This transducer is developed by vendor’s experts using best quality material in compliance with the set standard. The offered transducer is acknowledged among customers due to its superior performance. Moreover, our valuable customers can avail this transducer from us at nominal rates.

    Features:

    • Long life
    • Output which isolated from the input
    • Easy operation

    Specifications:
    AccuracyStandard : ± 0.5% of Span
    Optional : On Request
    DielectricStrength 2.5kV at 50Hz for 1 min. (Standard)
    4kV(Optional), across
    Casing - Input / Output / Auxiliary
    Input - Output
    Input - Auxiliary
    Output - Auxiliary
    Output - Output (Optional, subject to technical feasibility)
    AC InputVoltage: 63.5 / 110 / 230 / 440V (any one only)
    Current: 1A / 5A (any one only)
    Auxiliary110/230V AC ± 20%
    24/48/110/220V DC ± 20%
    Self powered Available. Refer PDF
    IsolationComplete (Input / Output / Auxiliary / Case)
    StandardsIEC 688 / EN 60688, EN 61010-1, EN 61326-1, IS12784 (Part-1) 1989
    TypeDIN Mounting, Back Panel Mounting
    DC OutputCurrent : 0-1, 0-5, 0-10, 2-10, 0-20, 4-20mA
    Voltage : 0-1, 0-5, 1-5, 0-10, 2-10V

    Additional Information:

  • Production Capacity: 2
  • Delivery Time: 30 Days
  • Yes! I am interested

    View PDF

    AC Voltage Transducers

    REQUEST CALLBACK

    AC Voltage Transducers
    Get Best Quote

    Thanks for Contacting Us.

    Approx. Rs 2,773 / eachGet Latest Price

    Product Details:
    Minimum Order Quantity1 each
    BrandMECO
    Model Name/NumberVMT
    Mounting TypeDin Rail
    Accuracy0.5

    Features:

    • These Transducers provide an output which is load independent and isolated from the input.
    • The output can be connected to Controllers, Data-Loggers, PLC''s, Analog / Digital Indicators, Recorders for display, analysis or control.
    • They are ideal for SCADA, Energy Management, Telemetering for Remote, Local as well as Central Monitoring Systems.

    Additional Information:

  • Production Capacity: 5
  • Delivery Time: 1 Week
  • Yes! I am interested

    View PDF

    DC Isolation Transducer

    REQUEST CALLBACK

    DC Isolation Transducer
    Ask for Price

    Thanks for Contacting Us.

    Product Price :Get Latest Price

    Our firm is involved in offering an extensive assortment of DC Isolation Transducer. These transducers are ideal for Energy Management, SCADA, telemetering for remote, local as well as central monitoring system. Offered transducers are designed from the optimum quality material & modern techniques in conformity with the set standard. The offered transducers are made accessible in various specifications to choose from.

    Features:

    • Excellent usage
    • Easy to operate
    • Comes with LED indication

    Specifications:
    TypeDIN Rail cum Wall Mounting
    DC OutputCurrent: 0-1,0-5,0-10,0-20,2-10,4-20mA DC
    Voltage: 0-1, 0-5, 1-5, 0-10, 2-10V DC
    AccuracyStandard : ± 0.5% of Span
    Optional : On Request
    IsolationComplete (Input / Output / Auxiliary / Case)
    Dielectric Strength2.5kV at 50Hz for 1 min. (Standard)
    4kV(Optional), across
    Casing - Input / Output / Auxiliary
    Input - Output
    Input - Auxiliary
    Output - Auxiliary
    Output - Output (Optional, subject to technical feasibility)
    StandardsIEC 688 / EN 60688, EN 61010-1, EN 61326-1, IS12784 (Part-1) 1989
    DC InputVoltage: 0-100mV, 0-1, 0-5, 1-5, 0-10, 2-10, 0-1000V DC
    Current: 4-20, 2-10, 1-5, 0-1, 0-10, 0-16, 0-20mA DC
    AuxiliarySMPS - HV : 85 - 265V AC /DC
    SMPS - LV : 19 - 90V AC / DC
    110/ 230V AC ± 20%
    Yes! I am interested

    View PDF

    Tap Position Transducer

    REQUEST CALLBACK

    Tap Position Transducer
    Ask for Price

    Thanks for Contacting Us.

    Product Price :Get Latest Price

    We are a Leading Trader & Supplier of Tap Position Transducer.

    Features:

    • The output can be connected to Controllers, Data-Loggers, PLC's Analog/Digital Indicators, Recorders for display, analysis or control.
    • They are ideal for SCADA, Energy Management, Telemetering for Remote, Local as well as Central Monitoring System.

    Models: TPT

    • Tap position Transducer takes various Resistance inputs and provides a Stable, Ripple-Free and Optically Isolated DC load independent output in the form of current or voltage.


    Specifications:

      TypeDIN Mounting, Back Panel Mounting
      DC OutputCurrent: 0-1, 0-5, 0-10, 2-10, 0-20, 4-20mA
      Voltage: 0-1, 0-5, 1-5, 0-10, 2-10V
      AccuracyStandard : ± 0.5% of Span
      Optional : On Request
      DielectricStrength 2.5kV at 50Hz for 1 min. (Standard)
      4kV(Optional), across
      Casing - Input / Output / Auxiliary
      Input - Output
      Input - Auxiliary
      Output - Auxiliary
      Output - Output (Optional, subject to technical feasibility)
      Resistance InputResistance input from potentiometric transformer
      tap position upto 99 transformer taps (100 KOhms max.)
      AuxillarySMPS - HV : 85-265V AC / DC
      SMPS - LV : 19-90V AC / DC
      110 / 230V AC ± 20%
      IsolationComplete (Input / Output / Auxiliary / Case)
      StandardsIEC 688 / EN 60688, EN 61010-1, EN 61326-1, IS12784 (Part-1) 1989
      Yes! I am interested

      View PDF

      Reactive Power Transducers

      REQUEST CALLBACK

      Reactive Power Transducers
      Ask for Price

      Thanks for Contacting Us.

      Product Price :Get Latest Price

      We are a Leading Trader & Supplier of Active Power (Watt) / Reactive Power (Var) Transducers. AC Active Power (Watt) & Reactive Power (Var) Transducers measure Power in 1 Phase, 3 Phase 3 Wire and 3 Phase 4 Wire in balanced or unbalanced electrical systems and converts it to an industry standard output signal which is directly proportional to the measured input.

      Features:

      • These Transducers provide an output which is load independent and isolated from the input.
      • These Transducers can measure both Import and Export of Power. The output can be connected to Controllers, Data-Loggers, PLC's Analog/Digital Indicators, Recorders for display, analysis or control.
      • They are ideal for SCADA, Energy Management, Telemetering for Remote, Local as well as Central Monitoring System


      Specifications:

      AC InputVoltage : 63.5 /110 /230 /440V (any one only)
      Current : 0-1 / 5A (any one only)
      TypeDIN Mounting, Back Panel Mounting
      DC OutputCurrent (mA) : 0-1, 0-5, 0-10, 2-10, 0-20, 4-20mA
      Voltage (V) : 0-1, 0-5, 1-5, 0-10, 2-10V
      Auxiliary110/ 230V AC ± 20%
      24/ 48/ 110/ 220V DC ± 20%
      Self powered Available. Refer PDF
      IsolationComplete (Input / Output / Auxiliary / Case)
      StandardsIEC 688 / EN 60688, EN 61010-1, EN 61326-1, IS12784 (Part-1) 1989
      AccuracyStandard : ± 0.5% of Span
      Optional : On Request
      DielectricStrength 2.5kV at 50Hz for 1 min. (Standard)
      4kV(Optional), across
      Casing - Input / Output / Auxiliary
      Input - Output
      Input - Auxiliary
      Output - Auxiliary
      Output - Output (Optional, subject to technical feasibility)
      Yes! I am interested

      View PDF

       
      X


      Explore More Products

      Contact via E-mail
      Contact via SMS
      Sri Meenakshi Enterprises
      Meyappan Thinnappan (CEO)
      No. 18, L. B. Road, Near Adyar Depot, Thiruvanmiyur , Adyar Bus Depot,
      Chennai - 600041, Tamil Nadu, India
      Call Us: 
      Call Response Rate: 95%
      Share Us :
      F G T L



      Home  |   About Us   |  What We Offer  |  Site Map  |   Contact Us

      © Sri Meenakshi Enterprises. All Rights Reserved (Terms of Use)
      Developed and Managed by IndiaMART InterMESH Limited